Why power is the first question
Before you think about shelving, door direction or what you'll store, look at refrigerated container power requirements. A refrigerated container, often called a reefer, is an insulated steel box with a refrigeration unit at one end. The box holds the cold. The unit makes it. And the unit only runs if the power at your spot matches what it was built for.
Get this wrong and you end up with a container that can't be switched on, a breaker that keeps tripping, or a rewiring job after delivery. Get it right first and the rest of the setup is straightforward.
This guide explains the electrical side in plain words, so you can have a useful conversation with your electrician. It doesn't replace that conversation. A licensed electrician should size the circuit, the wiring and the connection for any refrigerated container.
If you're still deciding whether a freezer container fits your business at all, start with our guide to restaurant cold storage containers. This post picks up where that one leaves off: the power.
Single-phase vs three-phase in plain words
Electric service comes in two common types.
Single-phase is what most homes, farms and small businesses run on. If your building has an ordinary breaker panel and you've never heard anyone mention "phase", you most likely have single-phase power.
Three-phase is common in larger commercial and industrial buildings, where big motors and heavy equipment run. It's delivered differently, and equipment built for it won't simply plug into single-phase service.
Why it matters for a reefer:
- Some refrigeration units are built for three-phase power. They can be a poor fit for a home, farm or small shop without it.
- Adding three-phase service where there isn't any is a job for your utility and electrician, and it isn't always practical.
- Single-phase units fit the service most small sites already have. That doesn't mean they'll run from any outlet. They still need a properly sized circuit.
If you don't know which service you have, your electrician can tell from the panel and meter. Your utility can also tell you.
Read the nameplate: voltage, amps, phase
Every refrigeration unit should carry a nameplate or data plate. It's usually a metal or printed label on the unit or inside its service panel. The plate lists the unit's electrical rating, typically including:
- Voltage: the supply voltage the unit is built for
- Phase: single-phase or three-phase
- Current (amps): how much current the unit draws
- Frequency: the cycle rate of the power supply
- Circuit protection: in some cases, the breaker or fuse size the maker calls for
Those figures, not a rule of thumb or a number from a forum, are what your electrician works from. Take a clear photo of the nameplate and send it to them before they visit. If you're buying a unit you can't see in person, ask the seller for a nameplate photo or the unit's electrical spec in writing.
We aren't giving amp or voltage figures in this guide on purpose. They vary by unit, and a number that's right for one freezer can be wrong for the next. Go by the plate.
What your electrician will check
A licensed electrician should size the circuit, but you'll save a visit if you know what they'll look at. In general, expect them to check:
- The nameplate of the refrigeration unit, as above.
- Your service and panel. Is there spare capacity for a refrigeration load, and is there room for a new breaker?
- The distance from the panel to the container spot. Longer runs can need heavier wire, and the route matters: buried, overhead or along a wall.
- A dedicated circuit. A freezer unit generally shouldn't share a circuit with other equipment.
- The outdoor connection. The container sits outside, so the connection, disconnect and wiring need to suit wet locations.
- Grounding of the unit and the steel box.
- Permits and inspection. Many cities and counties require an electrical permit for this kind of hookup. Your electrician works to the code adopted where you are.
Two things to skip: running a freezer unit from an extension cord, and doing the wiring yourself because "it's just a plug". If the electrician says your spot is a poor fit, it's usually easier to move the spot than to fight the wiring.
Generators and backup
A generator can run a refrigerated container where there's no grid power, or keep it cold during an outage. Plan it with the same care as the main hookup.
- Size it with help. Refrigeration compressors can draw more for a moment at start-up than while running. Ask your electrician or generator dealer to size the generator from the nameplate, not from a guess.
- Connect it properly. A standby generator tied into building wiring needs the right transfer equipment, installed by an electrician, so power can't feed back into utility lines.
- Keep it outside and away from openings. The EPA's carbon monoxide guidance says to use generators only outside and far from windows, doors and vents, and never inside a home or garage, even with doors and windows open. Never run one inside the container or right against its doors.
- Have an outage plan. Know who gets called, how long the doors stay shut and when stock gets checked or moved.
Placement: airflow around the unit
Power isn't the only site question. The refrigeration unit pulls in air and pushes heat out. If it can't breathe, it works harder and cools less.
- Leave clear space around the unit end. Don't back it against a wall, fence or another container. The unit's manual gives the clearance it needs.
- Keep the condenser clean. Leaves, dust and cottonwood fluff can clog it. Check it regularly through the summer.
- Shade helps, but airflow comes first. A spot out of the hottest afternoon sun is nice to have. A spot with good airflow around the unit is a must.
- Plan the power run with the spot. The spot with the most airflow may be a long way from the panel. Pick the spot with your electrician, not after.
Our guide on where to put a shipping container on your property covers drainage, door direction and truck access, which all apply to a reefer, too.
Our 20ft freezer: a new single-phase unit
Our 20ft refrigerated freezer container is a used, insulated reefer box fitted with a new 3.5 HP freezer unit that runs on single-phase power. Single-phase means it suits the type of service most small businesses, farms and homes already have. A licensed electrician still needs to size the circuit and connection for your site.
When you inquire, tell us about your power setup: what service you have, where the panel is and how far it is from the spot. We'll talk it through with you before you order.
Need refrigerated storage for wine or other stock rather than frozen goods? Our 40ft high cube wine cooler container uses a wall-mounted cooling unit. Tell us about your power supply so the cooling setup matches it. For lighting, outlets or other extras, see our electrical add-ons.
When a reefer isn't the right fit: if your site has no practical power source and a generator isn't an option, a refrigerated container will just be an insulated box. Sort out the power first.
Get a refrigerated container quoted
Send us your delivery ZIP, a photo of your electrical panel, the distance from the panel to the spot and what you'll store. We'll be in touch within 1 business day with a written quote that includes delivery and sales tax. Payment is by bank transfer, and our bank details come with the quote.
Request a quote for a refrigerated container. Delivery and sales tax are included.
Frequently asked questions
Can I plug a refrigerated container into a regular outdoor outlet?
Don't assume so. A freezer unit usually needs a circuit sized for its load. A licensed electrician should check the nameplate and your panel, then size the circuit and connection.
Do I need a permit to wire a refrigerated container?
Often, yes, but it depends on where you are. Your electrician will know whether your city or county requires an electrical permit and inspection for the hookup.